热99re久久精品这里都是精品免费-少妇爆乳无码av无码波霸-欧美人与动牲交精品-aⅴ网站在线观看-狠狠干b-日韩激情网址-亚洲成av人片在线观看ww-欧美视频网站-激情春色网-国产女人高潮抽搐叫床视频-人人射人人插-成年性生交大片免费看-久久久夜色精品-久久aⅴ乱码一区二区三区-日韩和的一区二区-亚洲精品国产av现线-天天干在线播放-99久热-亚洲色欲色欲www在线看-亚洲大尺度无码专区尤物

Contact Us

Mini Air Cooling Fan oil maintenance method of dry dead

Date: 2015-3-31   Click: 1645 Times

   ① "Mini Air Cooling Fan" direct damage, the judgment method for measuring motor windings with a multimeter X10 master file, the secondary winding (secondary winding is connected to the capacitor on the two yellow and black lines, red, white and blue primary winding for governor three), measure seer, a pen then yellow line when another branch red and blue, respectively, then the primary winding, the resistance is generally 400 - 600 ohm
   ② "Mini Air Cooling Fan" motor oil dry out and die, there is buzz when turned on, struck with a screwdriver blade, motor card refuses flexible
   Workaround: open the motor bearings and clean around the bearing hole, then the right amount of oil (oil), be careful not to rub with sandpaper motor bearings installed at one time, when not tighten the screws with a screwdriver around, banging motor Tighten adjusting screw shell before it, after the motor bearing flexible
   ③ "Mini Air Cooling Fan" motor capacitor damage, start slowly or does not start, there is buzz, poke can start
   Solution: Disconnect the cable capacitance, measured capacitance with X10K file, returning a pointer deflection after 1/4, otherwise capacitor damage (Box Fan 1 or 1.2μF, table fan 1.5μF)

Back to: Industry news

+86-0769-83660708

Home Product News Contact